EXTRG=0, DBLE=0, ADCS=00, ADST=0, GBADIE=0, TRGE=0
A/D Control Register
DBLANS | Double Trigger Channel Select |
GBADIE | Group B Scan End Interrupt and ELC Event Enable 0 (0): Disable ADC12i_GBADI (i = 0, 1) interrupt generation on group B scan completion. 1 (1): Enable ADC12i_GBADI (i = 0, 1) interrupt generation on group B scan completion. |
DBLE | Double Trigger Mode Select 0 (0): Deselect double-trigger mode. 1 (1): Select double-trigger mode. |
EXTRG | Trigger Select 0 (0): Start A/D conversion by the synchronous trigger (ELC). 1 (1): Start A/D conversion by the asynchronous trigger (ADTRG0). |
TRGE | Trigger Start Enable 0 (0): Disable A/D conversion to be started by the synchronous or asynchronous trigger 1 (1): Enable A/D conversion to be started by the synchronous or asynchronous trigger |
ADCS | Scan Mode Select 0 (00): Single scan mode 1 (01): Group scan mode 2 (10): Continuous scan mode 3 (11): Setting prohibited |
ADST | A/D Conversion Start 0 (0): Stop A/D conversion process. 1 (1): Start A/D conversion process. |